FAQ
• Search • Login
|
|
Page 1 of 1
|
[ 5 posts ] |
|
Detector issue in Toronto
Author |
Message |
Bert490
Joined: Fri Jul 03, 2015 7:04 pm Posts: 164 Location: Toronto Canada
|
My detector has become erratic, no clicks until I touch it, and one high reading when I touched the tube to ensure it was seated OK (GMC-200).
_________________https://netc.com/chart/view.php?n=1%3A919A925A.5 Toronto, Ontario, Canada SBM-20 indoors
|
Thu May 26, 2016 9:17 pm |
|
 |
KingCobra
Moderator
Joined: Mon Jan 28, 2013 7:40 pm Posts: 2889 Location: Illinois
|
I just looked at your chart.
1. Try a full reboot of your computer.
2. Try a new data cable.
3. If you have a backup GMC200 to connect, I'd suggest that.
When your unit is giving readings, they seem to be in the normal range most of the time. Most of your erratic readings fall to zero so maybe there is a loose connection on the GMC200 motherboard or maybe a bad data port/cable connection. Having a backup geiger counter works as a great way to trouble shoot your problem. Plus in the event that you get high radiation, you can verify quickly that your readings are correct.
_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier, ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C
|
Fri May 27, 2016 12:11 pm |
|
 |
Bert490
Joined: Fri Jul 03, 2015 7:04 pm Posts: 164 Location: Toronto Canada
|
It seems to be related to the detector. Clicks/flashes stop, then start when I touch it. The last recovery was due to just touching the negative end of the GM tube with my finger, it seems. Maybe I'll re-solder the connector.
_________________https://netc.com/chart/view.php?n=1%3A919A925A.5 Toronto, Ontario, Canada SBM-20 indoors
|
Fri May 27, 2016 10:55 pm |
|
 |
Lee971
Joined: Fri Mar 15, 2013 1:26 am Posts: 63 Location: Oklahoma City Area
|
I had one giving erratic spikes once. I wound up removing and resetting the GM tube. It seems to have solved the issue. In the process I bought another 200, 300E and a few extra tubes. Overkill? Not for me and my philosophy of two is one and one is none. Anyway, cheap insurance. For what it's worth.
_________________MY TWO RADIATION MONITORING STATIONS IN EDMOND OKLAHOMAOutside >> Air Filter,2nd Floor,GMC200, Indoor >> Window Sill,1st Floor,GMC300SITE OWNERS CAN POST STATIONS HERE."User Control Panel"~"Profile"~"Edit Signature"
|
Sat May 28, 2016 8:06 am |
|
 |
KingCobra
Moderator
Joined: Mon Jan 28, 2013 7:40 pm Posts: 2889 Location: Illinois
|
Lee971 wrote: I had one giving erratic spikes once. I wound up removing and resetting the GM tube. It seems to have solved the issue. In the process I bought another 200, 300E and a few extra tubes. Overkill? Not for me and my philosophy of two is one and one is none. Anyway, cheap insurance. For what it's worth. I had never heard that before, but I like it! In my life I have found it so helpful with troubleshooting things when having bought two of them.
_________________MY OUTSIDE RADIATION MONITORING STATION:South Beloit, Illinois - GMC200 Outside on HEPA air purifier, ground level, facing West. http://netc.com/chart/view.php?n=1%3AEB5A139C
|
Sat May 28, 2016 12:54 pm |
|
 |
|
|
Page 1 of 1
|
[ 5 posts ] |
|
Who is online |
Users browsing this forum: No registered users and 10 guests |
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot post attachments in this forum
|
|